Collage: a bearded engineer in a factory as a lime arrow jumps from a server rack across a row of robot arms and gears.
On this page (7)

In 2025, one of the operational technology (OT) systems of a dam facility in Bremanger, western Norway, was hit by a cyber operation. According to the Norwegian National Security Authority (NSM) (opens in a new tab), the intruders obtained remote access, changed settings in the control system and caused water to be released from the dam. The physical and economic consequences were limited. Norwegian authorities attribute the operation to a pro-Russian hacktivist group.

A year earlier, a very different flaw pointed at the same weakness. CVE-2024-6071, published in an advisory by the US Cybersecurity and Infrastructure Security Agency (CISA) (opens in a new tab), allowed anyone who could reach the web interface of a license server used with PTC’s Creo Elements/Direct design software to run operating system commands on that server, without credentials and without user interaction.

Neither case required advanced capabilities. That is the point. Industrial systems are rarely compromised because attackers are exceptionally skilled; they are compromised because a controller, a server or a remote access path is reachable, unowned and unsegmented. For CISOs, CIOs and executives of regulated operators in energy, water, manufacturing, chemicals or transport, the lesson is a governance one: protecting OT starts with decisions about ownership, exposure and acceptable risk, long before it becomes a question of tools.

Why OT incidents belong on the leadership agenda

In IT, a successful attack usually means lost data, fraud or downtime. In OT, the same intrusion can move a valve, stop a production line or disable a safety function. The consequences are physical: damage to equipment, harm to people, pollution, interruption of an essential service.

This changes who has to decide. The plant manager owns production targets, the engineering team owns the control systems, the integrator often owns remote maintenance, and the CISO is expected to secure all of it. When an incident happens, the questions asked by regulators, insurers and boards are not technical. Who knew this system was reachable? Who approved the connection? Who accepted the residual risk?

Key point: OT security is not a specialised branch of IT security that can be delegated to a single team. It is a shared risk between operations, engineering, safety and security, and it needs a named owner at leadership level.

What the Norwegian dam shows

The Bremanger case is instructive precisely because it was modest. In its National Threat Assessment 2026 (opens in a new tab), the Norwegian Police Security Service (PST) describes the operation as unsophisticated and with limited potential for damage. It nevertheless attracted considerable attention once the group publicised it on social media. PST places it among operations whose objective is to generate unrest and attract attention rather than to cause maximum harm.

Three lessons follow for operators.

First, the attacker did not need to break through layers of defence. NSM reports remote access to the control system followed by changes to its settings. Whatever the exact path, a system able to release water from a dam was reachable from outside.

Second, the impact on reputation and public trust can far exceed the physical damage. An operation designed to be filmed and shared turns a minor technical event into a national story. Communication plans for OT incidents need to exist before the video does.

Third, NSM stresses that such operations could have serious consequences if the infrastructure affected matters for essential services. Organisations should not size their defences on the intentions of the last attacker, but on what the next one could do with the same access.

Security implication: A hacktivist looking for visibility and a state-backed actor preparing sabotage may use the same exposed interface. The control that stops one stops the other: no direct reachability of control systems from untrusted networks.

What a license server vulnerability reveals

The CISA advisory ICSA-24-177-02, first published in June 2024 and updated in July 2024, describes CVE-2024-6071 as a missing authorization flaw (CWE-862) in the Creo Elements/Direct License Server. It carries the maximum CVSS score of 10.0, in both versions 3.1 and 4. CISA lists critical manufacturing among the sectors concerned and notes that the product is deployed worldwide. The fix is to upgrade the license server to version 20.7.0.1 or later. At the time of publication, CISA had received no report of public exploitation targeting the flaw.

A license server looks like a back-office component. In practice, it sits on networks used by engineering teams, often close to the systems that design and run production. An attacker who can execute commands on it gains a foothold inside a trusted zone, from which other systems become reachable.

The mitigations CISA recommends go beyond the patch, and they are the same for most industrial advisories: minimise network exposure so that control system devices are not accessible from the internet, place control networks behind firewalls and isolate them from business networks, use secure remote access methods while remembering that a VPN is only as secure as the devices connected to it, and carry out an impact analysis before deploying defensive measures.

For governance, the significance is in the last point. Patching in OT is not a routine IT task: it may require a production stop, vendor validation or a safety review. That is why emergency patching has become a governance decision rather than a hygiene task, and why compensating controls such as isolation must be decided, documented and owned while the fix waits for a maintenance window.

The common weakness: connected, unowned, unsegmented

The two cases differ in actor, sector and technique. They share a root cause that IT/OT convergence has made widespread.

Industrial environments were designed for safety and reliability, often on the assumption that they were isolated. Digitalisation has connected them to business networks, vendors’ remote maintenance tools, cloud analytics and IoT sensors. Each connection brings efficiency. Each one also creates a path that someone must own, monitor and be able to cut.

The NIST Guide to Operational Technology Security (SP 800-82 Rev. 3) (opens in a new tab) frames the problem clearly: OT covers a broad range of programmable systems and devices that interact with the physical environment, from industrial control systems to building automation, transportation and physical access control, and securing it means taking into account its specific performance, reliability and safety requirements. Applying IT practices unchanged can break a process; ignoring security because a system is “industrial” leaves it exposed.

In practice, three gaps recur:

  • Ownership gaps. Devices installed by an integrator, a facilities team or a vendor sit between IT and OT, and nobody is accountable for their security. The same pattern explains attacks on facility devices that keep essential services running.
  • Visibility gaps. Cellular modems, vendor tunnels and forgotten interfaces do not appear in standard scans. As detailed in our analysis of unmanaged network connections to critical services, the inventory often has to start with invoices and contracts rather than with tools.
  • Trust gaps. Operators and engineers rely on routine communications with colleagues, contractors and suppliers. An attacker who impersonates a vendor’s support line or steals a maintenance account inherits that trust. The techniques behind vishing attacks on identity systems apply equally to remote access into plants.

Executive takeaway: Most OT exposure is not created by attackers. It is created by connections the organisation itself added without assigning an owner, a justification and an end date.

Safety systems need an explicit security target

Safety instrumented systems (SIS) are the last line of defence in hazardous processes: they bring a plant to a safe state when conditions leave defined limits. A cyber compromise of a SIS removes that last barrier at the moment it is most needed.

The ISA/IEC 62443 series (opens in a new tab) addresses the security of industrial automation and control systems throughout their lifecycle and explicitly bridges process safety and cybersecurity. It assigns responsibilities to each stakeholder: asset owners, automation product suppliers, integrators and service providers. That allocation is itself a governance tool, because it makes clear that the asset owner cannot transfer accountability to its suppliers.

The series also defines four security levels. As summarised in ISA’s quick start guide to ISASecure certification (opens in a new tab), Security Level 1 is protection against casual or coincidental violation. Level 2 protects against intentional violation using simple means, low resources, generic skills and low motivation. Levels 3 and 4 address intentional violation using sophisticated means, IACS-specific skills and, respectively, moderate or extended resources and motivation.

These definitions give leaders a vocabulary to make an explicit choice. Security Level 1 can serve as a floor for SIS, but by definition it is not designed to resist an intentional attack. The Bremanger operation was unsophisticated, yet it was intentional. For SIS in energy, water treatment or chemical processing, the target level should be decided against the threat the operator actually faces, and the decision should be recorded and reviewed.

Decision point: Which security level does each safety-critical zone require, who signed off that choice, and when was it last compared with the current threat assessment?

What security leaders should prioritize

  1. Name an accountable owner for OT risk. Assign one executive role accountable for the security of operational systems across plants, sites and vendors, with authority over operations and engineering on connectivity decisions.
  2. Inventory every path into control systems. Map remote access, vendor tunnels, cellular links, license and engineering servers, and any interface reachable from business networks or the internet. Treat an unknown path as an open incident.
  3. Remove direct reachability. Apply CISA’s baseline: no control system device accessible from the internet, control networks isolated from business networks, remote access through approved and monitored gateways only.
  4. Decide patching and compensating controls together. For each critical OT advisory, document whether the fix is applied, when, and which isolation or monitoring measure covers the gap until then. Make the residual risk owner explicit.
  5. Set security levels for safety-critical zones. Use ISA/IEC 62443 to define the target level for each zone containing SIS or hazardous processes, and require suppliers and integrators to demonstrate how they meet it.
  6. Govern vendor and contractor access. Require named accounts, strong authentication, time-limited sessions and logging for every third-party connection, and verify identity for any request to open access or change settings.
  7. Rehearse an OT incident end to end. Run exercises that combine engineering, safety, security and communication teams, including the scenario of an attacker publishing evidence of access before the operator has detected it.

From technical findings to board-level evidence

Taken one by one, a CVE here, a dam there, a standard elsewhere, these events look like isolated news. Taken together, they show that OT risk is less about exotic attacks than about ordinary exposure left unmanaged, in environments where the consequences are physical.

Boards and regulators increasingly expect operators of essential services to demonstrate control, not just intent. That means evidence: an inventory of connections, a record of who approved each one, documented security levels for safety systems, patching decisions with named risk owners, and exercises that prove the organisation can respond. Those artefacts are what distinguish an organisation that was unlucky from one that was negligent.

The threat will keep changing. Hacktivists seek visibility, criminals seek leverage, other actors may prepare sabotage. The governance answer does not depend on which of them comes next: know what is connected, decide who owns it, limit what can reach it, and set the level of protection that safety requires.

Practical takeaway: Within the next quarter, ask for a single list of every system that can affect physical processes, with its owner, every path that reaches it and the security level decided for it. Any line without an owner, a justified path or a decided level is the first item on the remediation plan.

Sources

  1. NSM — Risiko 2026: Dagens valg – morgendagens risiko (opens in a new tab)
  2. PST — National Threat Assessment 2026 (opens in a new tab)
  3. CISA — PTC Creo Elements/Direct License Server (Update A) (ICSA-24-177-02) (opens in a new tab)
  4. NIST — SP 800-82 Rev. 3, Guide to Operational Technology (OT) Security (opens in a new tab)
  5. ISA — ISA/IEC 62443 Series of Standards (opens in a new tab)
  6. ISA — Quick Start Guide: An Overview of ISASecure Certification (opens in a new tab)

How we address this risk

Trusted Architecture

The design

Builds security into the design (Zero Trust, IAM/PAM, PKI), starting from the risks and the target governance.

Explore Trusted Architecture

Proof: Public transport operator

  • Critical infrastructure

    Why unmanaged network connections put critical services and customer trust at risk

    Every unmanaged network connection is a hidden doorway into your business, quietly exposing critical services and customer data to risks most organizations never see coming until it’s too late. Discover how overlooked links, forgotten devices, and unchecked access points can erode operations and undermine the trust your customers place in you, and learn where to start closing those gaps.

  • Critical infrastructure

    Why the HAProxy backdoor makes edge infrastructure a critical cyber risk

    Edge devices like load balancers and reverse proxies sit at the front door of your network, and when they’re compromised, attackers gain a privileged foothold that often goes unnoticed. This post examines how a backdoor in HAProxy-based infrastructure exposes that risk, why these systems are so attractive to attackers, and what security teams should be checking now.

Does this risk concern you?

Tell us about your context: an expert will get back to you.

Contact us

or write directly to trust@blooo.io

  • Reply within 24 hours
  • Non-disclosure agreement on request, before any exchange
  • First call of 30 minutes

Your e-mail is sent from your own mail client: blooo.io stores nothing. We only use your details to reply to you. Privacy policy.